Gilson offers unsurpassed flexibility in pumping systems with an extensive product range and accommodations. Gilson’s range of purification systems, components, and software provide the flexibility to create a purification system best suited to your needs.
Reliable and reproducible purification
Gilson’s range of pumps deliver reproducible and precise elution gradients to achieve repetitive isolations of targeted compounds with Gilson automated purification platforms.
Flexible for any task
From analytical to preparative chromatography, the large flow rate and pressure range from Gilson’s pumps can cover your purification needs. Driven by Gilson’s powerful TRILUTION® LC software, Gilson’s pumps provide extra flexibility with easily interchangeable pump heads and inlet solvent selectors.
Scale-up capabilities
With VERITY 3240, scale up purification from milligrams up to tens of grams on the same Gilson automated purification platform. VERITY 3011’s high pressure rating accommodates for industrial level applications in the petroleum industry.
SYSTEMS
VERITY® 3240 high pressure binary gradient pump
Semi-preparative to preparative HPLC
The VERITY® 3240 High Pressure Binary Gradient Pump is designed for semi-preparative to preparative purification. It provides an economical and compact pumping solution for preparative purification on 10 – 50 mm ID columns thanks to its large dynamic flow range up to 150 mL/min and pressure up to 420 bar (6090 psi).
VERITY 3240 has been designed to effectively allow for scaling up purification from milligrams up to tens of grams on the same Gilson automated purification platform. The large flow rate and pressure range allow the pump – 150 mL to cover most semi-preparative to preparative HPLC purification needs. VERITY 3240 can be equipped with inlet solvent selectors to support high throughput purification on different types of columns and to allow for quick column regeneration.
VERITY 3240 High Pressure Binary Gradient Pump
Gilson 322 HPLC pump
Analytical to semi-preparative HPLC
The Gilson 322 HPLC pump is a binary high pressure gradient solvent pump for analytical to semi-preparative scale HPLC. When configured with H2 pump heads, it is ideal for 4.6 – 20 mm ID columns with flows up to 30 mL/min and pressures up to 4,300 psi (300 bar).
Equipped with a High-pressure Adjustable Volume Dynamic Mixer (AVDM™) that enables fast gradient response times and homogeneous mixtures for analytical to semi-preparative applications. The adjustable mixing volume allows for easy methods switching from other HPLC system brands.
The Gilson 322 pump has two interchangeable pump heads that are easy to access and simple to maintain, to meet your application needs:
H1 pump heads: ideal for 2 – 12 mm ID columns with flows up to 15 mL/min and pressures up to 8,700 psi (600 bar)
H2 pump heads: ideal for 3 – 20 mm ID columns with flows up to 30 mL/min and pressures up to 4,300 psi (300 bar)
VERITY® 3011 isocratic pump
Automated GPC and analytical to semi-preparative HPLC
The VERITY® 3011 Isocratic Pump is an innovative liquid delivery solution for chemical reaction monitoring in petroleum applications and for gel permeation chromatography (GPC) in environmental and food and beverage testing applications. With Integrated touchscreen controller, VERITY 3011 offers convenient, stand-alone operation. When configured with a GX-271 Liquid Handler, VERITY® 4020 Single Syringe Pump and 157 UV/VIS Detector, VERITY 3011 delivers the mobile phase solvent for automated GPC or analytical to semi-preparative chromatography.
The VERITY 3011 Isocratic Pump features a virtually pulse-free, stable solvent flow rate, ensuring stable flow delivery to detectors, and allowing for a wider range of application capabilities on one pump. The pump also features an easily interchangeable quick-connect pump head, making maintenance simple and reducing costly downtime. The reproducibility and accuracy in reactions when using this pump, coupled with its low operation and maintenance costs, makes the VERITY 3011 Pump an ideal choice for many laboratories that pursue improved results with minimised costs, operators and downtime.
VERITY 3011 Isocratic Pump
Application Notes
Examples of application-based system configurations
Specifications
Pump model | VERITY 3240 | 322 | VERITY 3011 |
---|---|---|---|
Purification technique | Semi-prep to prep HPLC | Analytical to semi-prep HPLC | GPC and analytical to semi-prep HPLC |
Flow rate range | 0.1 – 150 mL/min | 0.015–15 mL/min (H1) 0.30 – 30 mL/min (H2) | 0.001 – 5 mL/min (5SS) 0.05 – 10 mL/min (10SS) |
Operating pressure (bar / psi) | 5 – 420 / 70 – 6090 (up to 110 mL/min) 5 – 320 / 70 – 4640 (from 110 - 150 mL/min) | 5 – 600 / 70 – 8700 (H1 pump head) 5 – 300 / 70 – 4350 (H2 pump head) | 0 – 600 / 0 – 8702 |
Flow accuracy | ± 1 % (min pressure of 10 bar) | ± 2 % | ± 2 % at 0.1 – 5 mL/min (5SS); at 0.1 – 10 mL/min (10SS) |
Flow precision | ≤ 0.3 % (from 15 - 150 mL/min) | ≤ 0.7% RSD | ≤ 1 % at 0.1 – 5 mL/min (5SS); at 0.1 – 10 mL/min (10SS) |
Hydraulic system | Reciprocating dual piston pumps | Reciprocating piston pump | Reciprocating single piston pump with passive dampening |